    Automated quantification and evaluation of motion artifact on coronary CT angiography images

    Get PDF
    Abstract Purpose This study developed and validated a Motion Artifact Quantification algorithm to automatically quantify the severity of motion artifacts on coronary computed tomography angiography (CCTA) images. The algorithm was then used to develop a Motion IQ Decision method to automatically identify whether a CCTA dataset is of sufficient diagnostic image quality or requires further correction. Method The developed Motion Artifact Quantification algorithm includes steps to identify the right coronary artery (RCA) regions of interest (ROIs), segment vessel and shading artifacts, and to calculate the motion artifact score (MAS) metric. The segmentation algorithms were verified against groundā€truth manual segmentations. The segmentation algorithms were also verified by comparing and analyzing the MAS calculated from groundā€truth segmentations and the algorithmā€generated segmentations. The Motion IQ Decision algorithm first identifies slices with unsatisfactory image quality using a MAS threshold. The algorithm then uses an artifactā€length threshold to determine whether the degraded vessel segment is large enough to cause the dataset to be nondiagnostic. An observer study on 30 clinical CCTA datasets was performed to obtain the groundā€truth decisions of whether the datasets were of sufficient image quality. A fiveā€fold crossā€validation was used to identify the thresholds and to evaluate the Motion IQ Decision algorithm. Results The automated segmentation algorithms in the Motion Artifact Quantification algorithm resulted in Dice coefficients of 0.84 for the segmented vessel regions and 0.75 for the segmented shading artifact regions. The MAS calculated using the automated algorithm was within 10% of the values obtained using groundā€truth segmentations. The MAS threshold and artifactā€length thresholds were determined by the ROC analysis to be 0.6 and 6.25 mm by all folds. The Motion IQ Decision algorithm demonstrated 100% sensitivity, 66.7% Ā± 27.9% specificity, and a total accuracy of 86.7% Ā± 12.5% for identifying datasets in which the RCA required correction. The Motion IQ Decision algorithm demonstrated 91.3% sensitivity, 71.4% specificity, and a total accuracy of 86.7% for identifying CCTA datasets that need correction for any of the three main vessels. Conclusion The Motion Artifact Quantification algorithm calculated accurate
    corecore